Resources · Field guides

Engineering Field Guides

Reference material for engineers who design, operate, and audit production infrastructure. Architecture standards, CLI procedures, and audit frameworks — written by WUC engineers from real engagement experience, not vendor marketing.

Maintained by WUC engineering Multi-OEM coverage: Cisco, NetApp, Pure, EMC, HPE, Brocade, Dell Updated as production patterns evolve

Library status

7 guides · published

8 guides · in pipeline

5 categories · ip-networking, architecture, storage, network, compute

Real engagements · not vendor docs

Category · 2 published · 0 in draft

IP Networking

Address planning, subnet design, and dual-stack readiness for production networks.

IP NETWORKING · IPv4 ADDRESSING

IPv4 Address Analyzer — Interactive Field Guide

Interactive subnet calculator with live CIDR / dotted-quad parsing, binary visualization, and RFC 1918 classifier. Covers historical IPv4 classes, supernetting, dual-stack readiness, and includes CLI cheat sheets for show ip interface, ip route, and arp across IOS, NX-OS, and JunOS.

~12 min read WUC Engineering Published May 2026

Read field guide
IP NETWORKING · IPv6 ADDRESSING

IPv6 Address Analyzer — Interactive Field Guide

Live parser for IPv6 notation with full classification per RFC 4291 (unicast scope), RFC 4193 (ULA), and RFC 6890 (special-purpose registry). Covers SLAAC vs DHCPv6, link-local fe80::/10 behavior, embedded IPv4 patterns, and the dual-stack interop checklist for production migration.

~14 min read WUC Engineering Published May 2026

Read field guide
Category · 1 published · 0 in draft

Architecture & Standards

Vendor-neutral engineering reference for design, audit, and capacity decisions.

INFRASTRUCTURE · ENGINEERING REFERENCE

Enterprise Data Center Rack Architecture — A Practical Field Guide

Standards (EIA-310-E, TIA-942-C, ASHRAE TC 9.9, Uptime Institute), airflow CFM/kW math, the WUC RACK-5 audit framework, the Dual-Rack Network Redundancy Pattern, and 11 engineering diagrams covering AI density, containment ROI, PUE, and Tier availability.

~25 min read WUC Engineering Practice Published May 2026

Read field guide
Category · 4 published · 5 in draft

Storage Operations

CLI references and change-control procedures for production storage fabrics.

CISCO MDS · SAN ZONING

Cisco MDS Zoning: A Field Guide for NetApp AFF Dual-Fabric Setups

CLI reference for creating zones, decommissioning hosts, and swapping HBA WWPNs during hardware replacement on Cisco MDS switches paired with NetApp AFF storage. Covers SIST best practice, show zone pending-diff safety gates, and host-side path verification on Linux, Windows, and ESXi.

~9 min read WUC Engineering Published May 2026

Read field guide
CISCO MDS · NX-OS COMMAND REFERENCE

Cisco MDS NX-OS Command Reference for Production SAN Operators

130+ read-only show commands across 11 categories — switch identity, environment, system health, processes, interfaces, FLOGI, FCNS, VSAN, zoning, device-alias, fabric-binding. Each command lists what it shows, when to run it, and a production-realistic output captured from MDS 9710 directors.

~25 min read WUC Engineering Published May 2026

Read field guide
DELL POWERSCALE · ONEFS COMMAND REFERENCE

Dell PowerScale (Isilon) OneFS Command Reference for Production Storage Operators

90+ OneFS commands across 9 families — cluster health, node hardware, SmartConnect networking, SmartPools and protection, AD/LDAP identity, hung-session recovery, performance, SyncIQ and CloudPools, ACLs. Every command is safety-rated read-only, disruptive, or destructive, with representative outputs, four incident runbooks, and a DR failover procedure.

~30 min read WUC Engineering Published July 2026

Read field guide
DELL POWERSCALE · DATA PROTECTION

PowerScale Data Protection: SmartPools Settings, Requested Protection, and What SmartFail Actually Does

Every SmartPools global setting explained — virtual hot spare, spillover, GNA, L3, and the “apply to manually-managed protection” checkbox that silently erases every override on the cluster. Plus the 2N+1 node-count rule that decides which protection levels are achievable, how to set 3x mirroring, and why a 3-node cluster refuses a SmartFail.

~16 min read WUC Engineering Published July 2026

Read field guide
In pipeline · 5 guides in draft
  • NetApp ONTAP aggregate & volume provisioning
  • Pure Storage host group + LUN setup
  • EMC VPLEX distributed device creation
  • HPE 3PAR / Primera virtual volume creation
  • Dell PowerStore volume migration
In pipeline · 1 guide coming

Network Operations

Fabric merges, zone imports, and switch configurations under change-control.

In pipeline · 1 guide in draft
  • Brocade fabric merge & zone import
In pipeline · 2 guides coming

Compute & Virtualization

Service profile deployment, datastore expansion, host commissioning under change-control.

In pipeline · 2 guides in draft
  • Cisco UCS service profile deployment
  • VMware vSphere datastore expansion under change control
Get a Custom Solution